Products

F-Charge Lead Carbon Battery

F-Charge Lead Carbon Battery

HDC series lead carbon batteries use functional activated carbon and graphene as carbon materials, which are added to the negative plate of the battery to make lead carbon batteries have the advantages of both lead-acid batteries and super capacitors. It not only improves the ability of rapid charge and discharge, but also greatly prolongs the battery life. It is more suitable for the application of PSOC.

  • Item NO.:HDC Series
  • Product Origin:China
  • Color:Red Body, Black Cover
  • Goods stock:480
  • Min order:48
  • Product weight:5-80 KGS
  • Lead Time:30-35 days, Fast Delivery 25days
  • Plate:Lead Carbon Flat Plate
  • Nominal Voltage:12V 6V
  • Discharge Rate:0.1-0.5C
  • Electrolyte:ACID
  • Welcome:OEM Brand, Color with Free
  • Usage:Solar/Wind/Telecom
  • Certificates:CE/IEC/ISO
  • Warranty:3-5Years
  • Trade Terms:EXW, FOB, CIF
Categories

Need Battery Urgent?

You can contact us in any way that is convenient for you. We are available 24/7 via: info@csbattery.cn or WhatsApp/WeChat: +8613612867133
New Products

CHARACTERISTICS

CSBattery HDC SERIES Fast Charge DEEP CYCLE Lead Carbon BATTERY

  • Voltage: 6V, 12V
  • Capacity: 6V200Ah~6V400Ah, 12V14Ah~12V250Ah
  • Designed floating service life: 15~20years @25°C/77°F

> Why the market need Lead Carbon battery

  • Failure modes of flat plate VRLA lead acid batteries in case of intensive cycling

The most common failure modes are:

– Softening or shedding of the active material. During discharge the lead oxide (PbO2) of the positive plate is transformed into lead sulfate (PbSO4), and back to lead oxide during charging. Frequent cycling will reduce cohesion of the positive plate material due to the higher volume of lead sulfate compared to lead oxide.

– Corrosion of the grid of the positive plate. This corrosion reaction accelerates at the end of the charge process due to the, necessary, presence of sulfuric acid.

– Sulfation of the active material of the negative plate. During discharge the lead (Pb) of the negative plate is also transformed into lead sulfate (PbSO4). When left in a low state-of-charge, the lead sulfate crystals on the negative plate grow and harden and form and impenetrable layer that cannot be reconverted into active material. The result is decreasing capacity, until the battery becomes useless.

  • It takes time to recharge a lead acid battery

Ideally, a lead acid battery should be charged a rate not exceeding 0,2C, and the bulk charge phase should be by eight hours of absorption charge. Increasing charge current and charge voltage will shorten recharge time at the expense of reduced service life due to temperature increase and faster corrosion of the positive plate due to the higher charge voltage.

  • Lead Carbon Battery: better partial state-of-charge performance, more cycles long life, and higher efficiency deep cycle

Replacing the active material of the negative plate by a lead carbon composite potentially reduces sulfation and improves charge acceptance of the negative plate.

> Features for Fast Charge Deep Cycle Lead Carbon battery

  • Combine the characteristics of lead acid battery and super capacitor
  • Long life cycle service design, excellent PSoC and cyclic performance
  • High power, rapid charging and discharging
  • Unique grid and lead pasting design
  • Extreme temperature tolerance
  • Able to operate at -30°C -60°C
  • Deep Discharge recovery capability

> Advantages  for Fast Charge Deep Cycle Lead Carbon battery

  • Less sulfation in case of partial state-of-charge operation.
  • Lower charge voltage and therefore higher efficiency and less corrosion of the positive plate.
  • And the overall result is improved cycle life.

Tests have shown that our lead carbon batteries do withstand at least eight hundred 100% DoD cycles.

The tests consist of a daily discharge to 10,8V with I = 0,2C₂₀, by approximately two hours rest in discharged condition, and then a recharge with I = 0,2C₂₀.

  • ≥ 1200 cycles @ 90% DoD (discharge to 10,8V with I = 0,2C₂₀, by approximately two hours rest in discharged condition, and then a recharge with I = 0,2C₂₀)

≥ 2500 cycles @ 60% DoD (discharge during three hours with I = 0,2C₂₀, immediately by recharge at I = 0,2C₂₀)

≥ 3700 cycles @ 40% DoD (discharge during two hours with I = 0,2C₂₀, immediately by recharge at I = 0,2C₂₀)

> Construction  for Fast Charge Deep Cycle Lead Carbon battery

CSBattery Lead Carbon Tech USE Three generations of technology Of Lead-Carbon Plates.

> Applications  for Fast Charge Deep Cycle Lead Carbon battery

  • Ø Solar power generation grid,       Ø Off Grid energy storage systems, Ø Wind Power Systems,
  • Ø Hybrid energy storage systems,  Ø Home energy storage systems,   Ø Telecom Station,
  • Ø Renewable energy storage,       Ø Smart power grids and micro-grids system,   Ø UPS Systems,
  • Ø Electric Powered Vehicles,        Ø Golf Cars and Buggies, Ø Tour bus, Ø Sweeper, Ø Floor cleaning machines,
  • Ø Wheel Chairs, Ø Power Tools, Ø Electric Powered Toys, Ø Control System, Ø Medical Equipments,
  • Ø Forklift, Ø Marine,  Ø RV, Ø Boat,  Ø Pumps,  and so on.

> HDC Delivery time

  • Normal, 30-35 days for production with injection molding Lead-Carbon-plate by ourself
  • As a factory we Can Support Urgent project with 25-30days.
  • OEM brand is Free service.
CONTACT CSBATTERY
While we’re good with smoke signals, there are simpler ways for us to get in touch and answer your questions.
Email *
Tel/WhatsApp *
Message *
PS: We guarantee that your information will be safety and will not be disclosed!

Related Products

OPzV Tubular Gel Battery
OPzV Series Tubular Plate with Pure Gel Supper long life Battery, Capacity: 2V100Ah~3000Ah. 12V100Ah, 150Ah,...
HTB High Temp Gel Battery
HTB (High Temperature Long Life Deep Cycle GEL Batteries) series is pure GEL battery with...
FB Front Terminal Battery
CSBattery Front Terminal lead acid battery is mainly used in the area of communication, which...
SX Deep Cycle Gel Solar Bat...
Solar Battery series is pure GEL Deep cycle battery with 15~20 years floating design life....
OPzS Tubular Flooded Battery
CSBattery OPzS series is flooded Lead Acid battery that adopts Tubular Plate technology to offer...
LifePO4 Replace SLA Battery
LFP Series Lithium Iron Phosphate ( LiFePO4 ) batteries are developed to deliver high efficiency...
LiFePO4 Batteries for 19'Rank
LPR series battery system is 48V/ 24V/ 12V system for communications back-up type LiFePO4 (lithium...
AGM VRLA battery
Lead Acid AGM VRLA Battery
CSBattery GB series is general AGM VRLA battery purpose storage battery with 12 years of...

What Are You Looking For?

CONTACT CSBATTERY

While we’re good with smoke signals, there are simpler ways for us to get in touch and answer your questions.

Email *
Tel/WhatsApp *
Message *
PS: We guarantee that your information will be safety and will not be disclosed!